X RAY SPECTRO 70X SELETRONIC – MOBILE COLUMN

Categories: ,

Description

X-Rays device with movable base, on four double casters, with brakes, providing good stability and improved approach to patient and enabling the use in more than one clinical room.

  • Swivel arms made of steel and steel with cover made of high-impact injected ABS, with horizontal reach of 1104 mm and vertical reach of 620 mm; mechanically balanced through springs that compensate the device weight, making the positioning of the head easy and, even in more difficult radiography.
  • Head with grounding system for increased operator protection; Toshiba brand imported bulb provides greater safety regarding the efficiency and durability based on international experience of manufacturer; two limiters in articulation offer protection to electrical cables.
  • Oil immersion ensures effective cooling and insulation, even in most intense uses.
  • Rubber expansion chamber with potential elasticity and size resistance ensures protection to the head, the operator and the patient, as the oil heated at high temperatures safely dilates, reducing the volumetric pressure and providing optimal cooling to head components, without leakage or explosion.
  • Total filtration with equivalence in 2.71mm aluminum releases the useful rays and retains the soft rays, eliminating the secondary radiation.
  • Primary collimator, placed after the aluminum filter, delimits the x-ray beam to the diameter of 59 mm at the output of positioning cylinder, reducing radiations on other directions and preventing the x-ray beam from reaching the cylinder walls; with good targeting, it reduces the irradiated area after the film, providing more protection to the patient.
  • Long guide cylinder, used to enable the flawless positioning of the film in relation to the x-ray beam; dimensioned for a 200mm focus-film system; lined with 0.5mm thickness lead plate, it retains the secondary radiation that may occasionally be formed in the primary collimation.
  • Secondary collimator, located at cylinder end, eliminates the secondary radiation that may be formed after the primary collimator, increasing the professional safety.
  • 0.8 x 0.8mm focal point provides greater sharpness and detail.
  • Goniometer used to achieve the desired inclination angle, scale-graded with divisions of 10 in 10 degrees, positive and negative as well.
  • 70 kVp rated voltage; due to the greater ray beam penetration power, it is possible to operate with less exposure time, reducing the probability for the tissues to absorb radiation, allowing a far superior observation of details in radiographies, including the soft tissues.
  • 8 mA current extends the service life of head components.
  • Command panel with main switch enables viewing when the device is switched on; embedded voltage regulator, avoids damage to the head and increases the device service life.
  • Digital remote control linked to command pane through spiral wire, including all controls grouped, enables controlling at a maximum distance of 3m out of the secondary radiation area, allowing visual monitoring by the operator; control with all predefined functions, where you made the selection of radiography type (periapical, interproximal and occlusal), type and position of tooth, film (layer or digital sensor) an age range of patient (adult or child); digital display with selected options; + and – key to increase or reduce the exposure time for any of the selections; R key (restore) – reset to default programs if one or more has been modified; S key (save) – saves changes in exposure times for any of the selections; trigger key that shall be pressed down during the entire exposure time, followed by an acoustic signal.
  • Automatic time compensation device automatically corrects the exposure time with high precision, according to electrical network fluctuations, always maintaining the radiation dosage, measured in milliampere-seconds, uniform.
  • Locking mechanism against accidental and consecutive triggers, eliminating unnecessary exposures to radiation and overheating.
  • Supply voltage 110V or 220V